Current Signature Analysis for Condition Monitoring of Cage Induction Motors : (Record no. 74489)

000 -LEADER
fixed length control field 05708nam a2200913 i 4500
001 - CONTROL NUMBER
control field 7823160
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20220712205943.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 170210s2016 nju ob 001 eng d
019 ## -
-- 965196180
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
ISBN 9781119175476
-- electronic bk.
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
-- print
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
-- electronic bk.
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
-- ebk
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
-- electronic bk.
082 04 - CLASSIFICATION NUMBER
Call Number 621.34
100 1# - AUTHOR NAME
Author Thomson, William T.,
245 10 - TITLE STATEMENT
Title Current Signature Analysis for Condition Monitoring of Cage Induction Motors :
Sub Title Industrial Application and Case Histories /
300 ## - PHYSICAL DESCRIPTION
Number of Pages 1 PDF (440 pages).
490 1# - SERIES STATEMENT
Series statement IEEE press series on power engineering
505 0# - FORMATTED CONTENTS NOTE
Remark 2 Motor Current Signature Analysis for Induction Motors / William T Thomson -- Design, Construction, and Manufacture of Squirrel Cage Rotors / Ian Culbert -- Causes of Breaks in Squirrel Cage Windings During Direct-On-Line Starts and Steady-State Operation / Ian Culbert -- Motor Current Signature Analysis (MCSA) to Detect Cage Winding Defects / William T Thomson -- MCSA Industrial Case Histories-Diagnosis of Cage Winding Defects in SCIMs Driving Steady Loads / William T Thomson -- MCSA Case Histories-Diagnosis of Cage Winding Defects in SCIMs Fitted with End Ring Retaining Rings / William T Thomson -- MCSA Case Histories-Cyclic Loads Can Cause False Positives of Cage Winding Breaks / William T Thomson -- MCSA Case Histories-SCIM Drives With Slow Speed Gearboxes and Fluctuating Loads Can Give False Positives Of Broken Rotor Bars -- Miscellaneous MCSA Case Histories / William T Thomson -- MCSA to Estimate the Operational Airgap Eccentricity in Squirrel Cage Induction Motors / William T Thomson -- Case Histories-Successful and Unsuccessful Application of MCSA to Estimate Operational Airgap Eccentricity in Scims / William T Thomson -- Critical Appraisal of Mcsa to Diagnose Short Circuited Turns in LV and HV Stator Windings and Faults in Roller Element Bearings in SCIMS / William T Thomson -- Appraisal of MCSA Including Lessons Learned via Industrial Case Histories / William T Thomson -- List of Equations.
520 ## - SUMMARY, ETC.
Summary, etc Provides coverage of Motor Current Signature Analysis (MCSA) for cage induction motors This book has 13 chapters and contains a unique database of 50 industrial case histories on theapplication of MCSA to diagnose broken rotor bars or unacceptable levels of airgap eccentricity in cage induction motors with ratings from 127 kW (170 H.P.) to 10,160 kW (13,620 H.P.). There are also unsuccessful case histories which is another unique feature of the book. The case studies also illustrate the effects of mechanical load dynamics downstream of the motor on the interpretation of current signatures. A number of cases are presented where abnormal operation of the driven loadwas diagnosed. Other unique features include: . All case histories are presented in a step-by-step format, with predictions and outcomes supported by current spectra and photographic evidence to confirm a correct orincorrect diagnosis. Chapter 13 presents a critical appraisal of MCSA including successes, failures, and lessons learned via industrial case studies. There are 10 questions at the end of chapters 1 to 12 and answers can be obtained viathe publisher Current Signature Analysis for Condition Monitoring of Cage Induction Motors: Industrial Application and Case Histories serves as a reference for professional engineers, head electricians and technicians working with induction motors.
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1
Subject Electric motors, Induction
General subdivision Testing.
650 #7 - SUBJECT ADDED ENTRY--SUBJECT 1
Subject Electric motors, Induction
General subdivision Testing.
700 1# - AUTHOR 2
Author 2 Culbert, Ian.
856 42 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier https://ieeexplore.ieee.org/xpl/bkabstractplus.jsp?bkn=7823160
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type eBooks
264 #1 -
-- Hoboken, New Jersey :
-- Wiley :
-- IEEE Press,
-- 2016.
264 #2 -
-- [Piscataqay, New Jersey] :
-- IEEE Xplore,
-- [2016]
336 ## -
-- text
-- rdacontent
337 ## -
-- electronic
-- isbdmedia
338 ## -
-- online resource
-- rdacarrier
588 ## -
-- Description based on PDF viewed 02/10/2017.
695 ## -
-- Aluminum
695 ## -
-- Amplitude modulation
695 ## -
-- Bars
695 ## -
-- Circuit faults
695 ## -
-- Coal
695 ## -
-- Computer aided software engineering
695 ## -
-- Copper
695 ## -
-- Couplings
695 ## -
-- Current measurement
695 ## -
-- Fluids
695 ## -
-- Frequency measurement
695 ## -
-- Harmonic analysis
695 ## -
-- Heating
695 ## -
-- History
695 ## -
-- Induction motors
695 ## -
-- Industries
695 ## -
-- Insulation
695 ## -
-- Magnetic circuits
695 ## -
-- Magnetic cores
695 ## -
-- Magnetic flux
695 ## -
-- Rotors
695 ## -
-- Shafts
695 ## -
-- Shape
695 ## -
-- Stator cores
695 ## -
-- Stator windings
695 ## -
-- Stress
695 ## -
-- Vibrations
695 ## -
-- Windings

No items available.