Computer-Aided Detection of Architectural Distortion in Prior Mammograms of Interval Cancer (Record no. 85622)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 05041nam a22005295i 4500 |
001 - CONTROL NUMBER | |
control field | 978-3-031-01656-1 |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20240730164352.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 220601s2013 sz | s |||| 0|eng d |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
ISBN | 9783031016561 |
-- | 978-3-031-01656-1 |
082 04 - CLASSIFICATION NUMBER | |
Call Number | 620 |
100 1# - AUTHOR NAME | |
Author | Banik, Shantanu. |
245 10 - TITLE STATEMENT | |
Title | Computer-Aided Detection of Architectural Distortion in Prior Mammograms of Interval Cancer |
250 ## - EDITION STATEMENT | |
Edition statement | 1st ed. 2013. |
300 ## - PHYSICAL DESCRIPTION | |
Number of Pages | XX, 176 p. |
490 1# - SERIES STATEMENT | |
Series statement | Synthesis Lectures on Biomedical Engineering, |
505 0# - FORMATTED CONTENTS NOTE | |
Remark 2 | Introduction -- Detection of Early Signs of Breast Cancer -- Detection and Analysis of Oriented Patterns -- Detection of Potential Sites of Architectural Distortion -- Experimental Set Up and Datasets -- Feature Selection and Pattern Classification -- Analysis of Oriented Patterns Related to Architectural Distortion -- Detection of Architectural Distortion in Prior Mammograms -- Concluding Remarks. |
520 ## - SUMMARY, ETC. | |
Summary, etc | Architectural distortion is an important and early sign of breast cancer, but because of its subtlety, it is a common cause of false-negative findings on screening mammograms. Screening mammograms obtained prior to the detection of cancer could contain subtle signs of early stages of breast cancer, in particular, architectural distortion. This book presents image processing and pattern recognition techniques to detect architectural distortion in prior mammograms of interval-cancer cases. The methods are based upon Gabor filters, phase portrait analysis, procedures for the analysis of the angular spread of power, fractal analysis, Laws' texture energy measures derived from geometrically transformed regions of interest (ROIs), and Haralick's texture features. With Gabor filters and phase-portrait analysis, 4,224 ROIs were automatically obtained from 106 prior mammograms of 56 interval-cancer cases, including 301 true-positive ROIs related to architectural distortion, and from 52 mammograms of 13 normal cases. For each ROI, the fractal dimension, the entropy of the angular spread of power, 10 Laws' texture energy measures, and Haralick's 14 texture features were computed. The areas under the receiver operating characteristic (ROC) curves obtained using the features selected by stepwise logistic regression and the leave-one-image-out method are 0.77 with the Bayesian classifier, 0.76 with Fisher linear discriminant analysis, and 0.79 with a neural network classifier. Free-response ROC analysis indicated sensitivities of 0.80 and 0.90 at 5.7 and 8.8 false positives (FPs) per image, respectively, with the Bayesian classifier and the leave-one-image-out method. The present study has demonstrated the ability to detect early signs of breast cancer 15 months ahead of the time of clinical diagnosis, on the average, for interval-cancer cases, with a sensitivity of 0.8 at 5.7 FP/image. The presented computer-aided detection techniques, dedicated to accurate detection and localization of architectural distortion, could lead to efficient detection of early and subtle signs of breast cancer at pre-mass-formation stages. Table of Contents: Introduction / Detection of Early Signs of Breast Cancer / Detection and Analysis of Oriented Patterns / Detection of Potential Sites of Architectural Distortion / Experimental Set Up and Datasets / Feature Selection and Pattern Classification / Analysis of Oriented Patterns Related to Architectural Distortion / Detection of Architectural Distortion in Prior Mammograms / Concluding Remarks. |
700 1# - AUTHOR 2 | |
Author 2 | Rangayyan, Rangaraj. |
700 1# - AUTHOR 2 | |
Author 2 | Desautels, J.E. Leo. |
856 40 - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | https://doi.org/10.1007/978-3-031-01656-1 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Koha item type | eBooks |
264 #1 - | |
-- | Cham : |
-- | Springer International Publishing : |
-- | Imprint: Springer, |
-- | 2013. |
336 ## - | |
-- | text |
-- | txt |
-- | rdacontent |
337 ## - | |
-- | computer |
-- | c |
-- | rdamedia |
338 ## - | |
-- | online resource |
-- | cr |
-- | rdacarrier |
347 ## - | |
-- | text file |
-- | |
-- | rda |
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Engineering. |
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Biophysics. |
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Biomedical engineering. |
650 14 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Technology and Engineering. |
650 24 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Biophysics. |
650 24 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Biomedical Engineering and Bioengineering. |
830 #0 - SERIES ADDED ENTRY--UNIFORM TITLE | |
-- | 1930-0336 |
912 ## - | |
-- | ZDB-2-SXSC |
No items available.